Author Ah Young Choi, MD, Su Youn Park, MD, Koung Hoon Kook, MD, PhD
Place of duty Department of Ophthalmology, Ajou University School of Medicine, Suwon, Korea
Title Repair of Inferomedial Orbital Wall Fractures with Bony Strut Loss by Overlapping Absorbable Copolymer
Publicationinfo J Korean Ophthalmol Soc 2013 Sep 054(09): 1315-1320.
Key_word Bony strut, Inferomedial orbital wall fracture, Orbital implant, Overlapping method
Full-Text
Abstract Purpose: To report the results of surgical repairing of inferomedial orbital wall fractures accompanied with loss of bony strut by an overlapping method using Resorb X® plates (poly(D,L)-lactic acid). Methods: To repair inferomedial orbital wall fractures with loss of bony strut, we bent the medial aspect of the plate for floor fracture according to the anatomical structure and then inserted the floor implant, which was supported by anterior, posterior and lateral margins of the floor fracture. Then, the medial implant, which was supported by the bent medial edge of the floor implant, was inserted. Postoperatively, we analyzed the outcomes of 21 patients regarding postoperative enophthalmos, limitation of eye movement (LOM) and diplopia. The diagonal lengths of the orbit in the operated side were compared with the non-traumatized side based on the coronal view of the postoperative CT scans to determine the success or failure of the reconstruction. Results: The average postoperative enophthalmic value was 0.5 mm, and no significant differences between the orbital diagonal lengths of the operated and non-operated eyes were observed. The LOM shown in 7 out of 8 patients was completely resolved during the postoperative follow-up period. All patients with diplopia, including one patient who showed partial remission of LOM, experienced complete symptom resolution. No other complications related to the implant were recorded. Conclusions: Inferomedial orbital wall fractures with the loss of bony strut can be successfully repaired by the overlapping method using Resorb X® implants.
저 자 최아영⋅박수연⋅국경훈
소 속 아주대학교 의과대학 안과학교실
제 목 경계골 소실이 동반된 안와내하벽골절에서 생체흡수성 코폴리머의 겹치기 방법을 이용한 정복술
출판정보 대한안과학회 2013 Sep 054(09): 1315-1320.
키워드 Bony strut, Inferomedial orbital wall fracture, Orbital implant, Overlapping method
초 록 목적: 경계골(bony strut) 소실이 동반된 안와내하벽골절 환자에서 Resorb X® (poly(D,L)-lactic acid)를 사용하여 두 삽입물이 겹치게 삽입하는 방법을 통한 정복술의 결과를 보고하고자 하였다. 대상과 방법: 경계골 소실을 동반한 안와내하벽골절에 대한 복원 수술 시행시, Resorb X® 를 이용해 하벽삽입물의 내측면을 경계골의 형태에 맞게 구부려 삽입하고 구부린 부분을 내벽삽입물의 하측 지지대로 이용하여 내벽삽입물을 삽입하는 겹치기방법을 통해 정복술 을 시행 받았던 21명의 단안 골절 환자를 대상으로 하여, 술 후 안와전산화단층촬영의 관상단면에서 안와상외측 경계점으로부터 하내 측 경계골부위까지의 안와 대각선 길이를 측정하고 양측을 비교 분석함으로써 경계골 소실에 대한 복원 여부를 판정하였다. 또한 의무 기록 검토로 술 후 경과 관찰 중 안구함몰 및 안구운동장애의 잔존 혹은 발생 여부, 그리고 합병증발생 여부를 확인하였다. 결과: 술 후 안와대각선길이는 양측 안와사이에 유의한 차이가 없었으며 평균 안구함몰은 0.5 mm였다. 술 전 안구운동장애가 있던 8명 중 7명이 술 후 경과 관찰 중 완전 소실되었고, 1명에서 상전 시 경미한 운동장애가 잔존하였으나 복시를 호소하지는 않았다. 그 외 삽입물과 관련된 합병증의 발생은 관찰되지 않았다. 결론: 경계골 소실이 동반된 안와내하벽골절 환자에서 Resorb X® 로 겹치기 방법을 통한 안와골절 정복술은 효과적인 수술방법이라 할 수 있겠다.