대한안과학회 학술대회 발표 연제 초록
 
백굴F-018
서로 다른 지지부 디자인의 3가지 일체형 아크릴 인공수정체 삽입 후의 수정체전낭 안정성 비교
가톨릭대학교 의과대학 서울성모병원 안과 및 시과학교실
이지현⋅이지혜⋅강민지⋅황웅주⋅변용수⋅이현수⋅정소향⋅주천기
목적 : To compare the anterior capsule contraction and IOL decentration among 3 types of intraocular lens to determine the influence of haptic design on anterior capsule stability. 방법 : 260 eyes of one hundred fifty patients were enrolled in this prospective, randomized study and underwent implantation of one of the following IOLs: modified L-haptic IOL (n=74), modified C-haptic IOL(n=97), or a plate-haptic IOL (n=89). The area of the anterior capsule opening, intraocular lens decentration, and capsule overlap were measured using retroillumination photospot at one day and two months after cataract surgery. 결과 : The area of capsule opening at postoperative 1day was significantly different among the three IOLs (P <0.01). All IOLs showed reduction of the anterior capsule opening from 1day to 2months after surgery, and greater reduction was shown in the modified C-haptic IOL (p<0.001). At postoperative 2month, IOL decentration was significantly different among the IOLs and showed positive correlation with the mean area reduction during 2month. 결론 : Degree of anterior capsule contraction and IOL decentration in modified L-haptic IOL were less than those in modified C-haptic IOL and comparable to those in plate-haptic IOL.
 