대한안과학회 학술대회 발표 연제 초록
 
발표일자: 2014년 4월 12일(토) ~ 4월 13일(일)
발표번호: P(e-poster)-072
발표장소: 킨텍스 제2전시장 7B홀
Accuracy of intraocular lens power calculation formulas after combined phacovitrectomy
가톨릭의과대학 안과학교실
지동현, 박이령,
목적 : AIM: To examine the accuracy of intraocular lens (IOL) power calculation formulas after phacovitrectomy. 방법 : METHODS: This retrospective study included one hundred one eyes (21 high myopic eyes and 80 non-high myopic eyes) of 101 patients who underwent phacovitrectomy (phacoemulsification, IOL implantation, and pars plana vitrectomy). The predicted post-operative refraction error was calculated with 4 commonly available IOL power formulas such as Hoffer Q, Holladay 1, Holladay 2, and SRK/T. With each formula, the mean error and the mean absolute error were calculated. The subjects were divided into 21 highly myopic eyes (AL>26.0mm); and 80 non-highly myopic eyes (AL≤26.0mm) 결과 : RESULTS: The mean error and the mean absolute error after phacovitrectomy did not show a significant difference among the 4 IOL power formulas (P=0.635, P=0.586). The formulas were also equally accurate when the patients were grouped into high myopic and non-high myopic eyes. 결론 : CONCLUSION: The 4 IOL calculation formulas provided equivalent performance in the subsets of axial lengths after phacovitrectomy.
 
[돌아가기]