대한안과학회 학술대회 발표 연제 초록
 
망막F-007
저강도 초음파의 경공막을 통한 혈장단백질 이동에 미치는 영향
¹성균관대학교 의과대학 강북삼성병원 안과, ²연세대학교 의과대학 안과학교실
배정훈1, 김양재1, 박한석1, 장효주1, 김찬윤2
목적 : To demonstrate the effect of low-intensity ultrasound on enhancing the transscleral delivery of serum protein into the eye. 방법 : Fifteen New Zealand white rabbits received 0.1 ml of 0.1% fluorescein isothiocyanate conjugated bovine serum albumin (FITC-BSA) solution as a subtenon injection in both eyes. Ultrasound at 1 MHz with an intensity of 240 mW/cm2 was applied over the injection site in the right eye for 5 minutes. The left eye served as a control. Both eyes were enucleated, and the whole vitreous was extracted from an eye. Fluorescence concentration in vitreous samples was measured. The penetration of FITC-BSA into the sclera was evaluated with the cryosectioned tissues using fluorescence microscope. 결과 : The mean concentration of vitreous fluorescence was 1.367 ± 0.309 μg/ml in the ultrasound-applied group and 1.101 ± 0.240 μg/ml in the control group, and the difference was statistically significant (P = 0.023, Mann-Whitney U test). It was also found that the scleral penetration of FITC-BSA was increased in the ultrasound-applied group compared to the control group. 결론 : Low-intensity ultrasound could enhance the transscleral protein delivery into the eye, suggesting that this technique may be a useful noninvasive alternative for intraocular drug delivery.
 